Facets (new session)
Description
Metadata
Settings
owl:sameAs
Inference Rule:
b3s
b3sifp
dbprdf-label
facets
http://dbpedia.org/resource/inference/rules/dbpedia#
http://dbpedia.org/resource/inference/rules/opencyc#
http://dbpedia.org/resource/inference/rules/umbel#
http://dbpedia.org/resource/inference/rules/yago#
http://dbpedia.org/schema/property_rules#
http://www.ontologyportal.org/inference/rules/SUMO#
http://www.ontologyportal.org/inference/rules/WordNet#
http://www.w3.org/2002/07/owl#
ldp
oplweb
skos-trans
virtrdf-label
None
About:
Nasopharyngeal Swabs Are More Sensitive Than Oropharyngeal Swabs for COVID-19 Diagnosis and Monitoring the SARS-CoV-2 Load
Goto
Sponge
NotDistinct
Permalink
An Entity of Type :
schema:ScholarlyArticle
, within Data Space :
wasabi.inria.fr
associated with source
document(s)
Type:
Academic Article
research paper
schema:ScholarlyArticle
New Facet based on Instances of this Class
Attributes
Values
type
Academic Article
research paper
schema:ScholarlyArticle
isDefinedBy
Covid-on-the-Web dataset
title
Nasopharyngeal Swabs Are More Sensitive Than Oropharyngeal Swabs for COVID-19 Diagnosis and Monitoring the SARS-CoV-2 Load
Creator
Zhou, Min
Xu, Dong
Wang, Huan
Li, Wen
Wang, Feng
Liu, Qian
Yin, Ping
Li, Yu
Hu, Jing
Kozlakidis, Zisis
Xiao, Yao
Li, Kai-Yan
Lu, Yan-Jun
Xu, Shu-Yun
Yang, Jun-Yi
Yu, Mu-Qing
Zhang, Huanping
source
Medline; PMC
abstract
Objective: Detection of SARS-CoV-2 by oropharyngeal swabs (OPS) and nasopharyngeal swabs (NPS) is an essential method for coronavirus disease 2019 (COVID-19) management. It is not clear how detection rate, sensitivity, and the risk of exposure for medical providers differ in two sampling methods. Methods: In this prospective study, 120 paired NPS and OPS specimens were collected from 120 inpatients with confirmed COVID-19. SARS-CoV-2 nucleic acid in swabs were detected by real-time RT-PCR. The SARS-CoV-2 detection rate, sensitivity, and viral load were analyzed with regards NPS and OPS. Sampling discomfort reported by patients was evaluated. Results: The SARS-CoV-2 detection rate was significantly higher for NPS [46.7% (56/120)] than OPS [10.0% (12/120)] (P < 0.001). The sensitivity of NPS was also significantly higher than that of OPS (P < 0.001). At the time of sampling, the time of detectable SARS-CoV-2 had a longer median duration (25.0 vs. 20.5 days, respectively) and a longer maximum duration (41 vs. 39 days, respectively) in NPS than OPS. The mean cycle threshold (Ct) value of NPS (37.8, 95% CI: 37.0–38.6) was significantly lower than that of OPS (39.4, 95% CI: 38.9–39.8) by 1.6 (95% CI 1.0–2.2, P < 0.001), indicating that the SARS-CoV-2 load was significantly higher in NPS specimens than OPS. Patient discomfort was low in both sampling methods. During NPS sampling, patients were significantly less likely to have nausea and vomit. Conclusions: NPS had significantly higher SARS-CoV-2 detection rate, sensitivity, and viral load than OPS. NPS could reduce droplets production during swabs. NPS should be recommended for diagnosing COVID-19 and monitoring SARS-CoV-2 load. Chinese Clinical Trial Registry, number: ChiCTR2000029883.
has issue date
2020-06-18
(
xsd:dateTime
)
bibo:doi
10.3389/fmed.2020.00334
bibo:pmid
32626720
has license
cc-by
sha1sum (hex)
113b304ee47b4fa103acf8abfc7d3f5a5efa0df7
schema:url
https://doi.org/10.3389/fmed.2020.00334
resource representing a document's title
Nasopharyngeal Swabs Are More Sensitive Than Oropharyngeal Swabs for COVID-19 Diagnosis and Monitoring the SARS-CoV-2 Load
has PubMed Central identifier
PMC7314917
has PubMed identifier
32626720
schema:publication
Front Med (Lausanne)
resource representing a document's body
covid:113b304ee47b4fa103acf8abfc7d3f5a5efa0df7#body_text
is
schema:about
of
named entity 'sensitivity'
named entity 'management'
named entity 'swabs'
named entity 'Detection'
named entity 'Load'
named entity 'SARS-CoV-2'
named entity 'COVID-19'
named entity 'COVID-19'
named entity 'Oropharyngeal'
named entity '37 days'
named entity 'visual analog scale'
named entity 'comorbidities'
named entity 'prospective study'
named entity 'COVID-19'
named entity 'OPS'
named entity 'influenza'
named entity 'vomit'
named entity 'OPS'
named entity 'nausea'
named entity 'SARS-CoV-2'
named entity 'SARS-CoV-2'
named entity 'OPS'
named entity 'electronic medical records'
named entity 'design of the study'
named entity 'symptom'
named entity 'SARS-CoV-2'
named entity 'quarantine'
named entity 'SARS-CoV-2'
named entity 'sample size'
named entity 'SARS-CoV-2'
named entity 'prospective study'
named entity 'OPS'
named entity 'RT-PCR'
named entity '3.5'
named entity 'PCR'
named entity 'OPS'
named entity '21 days'
named entity 'cough'
named entity 'face mask'
named entity 'vomit'
named entity 'OPS'
named entity 'OPS'
named entity 'OPS'
named entity 'OPS'
named entity 'COVID'
named entity 'OPS'
named entity 'clinical characteristics'
named entity 'OPS'
named entity 'nostril'
named entity 'RT-PCR'
named entity 'OPS'
named entity 'Beijing'
named entity 'McNemar's test'
named entity 'OPS'
named entity 'reverse transcription'
named entity 'influenza'
named entity '1.6'
named entity 'vomit'
named entity 'sampling methods'
named entity 'OPS'
named entity 'Wuhan'
named entity 'infection'
named entity 'OPS'
named entity 'lachrymation'
named entity 'sneezing'
◂◂ First
◂ Prev
Next ▸
Last ▸▸
Page 1 of 5
Go
Faceted Search & Find service v1.13.91 as of Mar 24 2020
Alternative Linked Data Documents:
Sponger
|
ODE
Content Formats:
RDF
ODATA
Microdata
About
OpenLink Virtuoso
version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software