About: BACKGROUND: The global market for SARS-CoV-2-immunoassays is becoming ever more crowded with antibody-tests of various formats, targets and technologies, careful evaluation is crucial for understanding the implications of individual test results. Here, we evaluate the clinical performance of five automated immunoassays on a set of clinical samples. METHODS: Serum/plasma samples of 75 confirmed COVID-19 patients and 320 pre-pandemic serum samples of healthy blood donors were subjected to two IgG and three total antibody SARS-CoV-2-immunoassays. All test setups were automated workflows. RESULTS: Positivity of assays (onset of symptoms > 10 days) ranged between 68.4% and 81.6% (Diasorin 68.4%, Euroimmun 70.3%, Siemens 73.7%, Roche 79.0% and Wantai 81.6%). All examined assays demonstrated high specificity of >99% (Euroimmun, Diasorin: 99.1%, Wantai: 99.4%) but only two reached levels above 99.5% (Roche: 99.7%, Siemens 100%). Interestingly, there was no overlap in false positive results between the assays. The strongest correlation of quantitative results was observed between the Diasorin and Euroimmun IgG tests (r(2) = 0.76). Overall, we observed no difference in the distribution of test results between female and male patients (p-values: 0.18-0.87). A significant difference between severely versus critically ill patients was demonstrated for the Euroimmun, Diasorin, Wantai and Siemens assays (p-values < 0.041). CONCLUSION: All assays showed good clinical performance. Our data confirm that orthogonal test strategies as recommended by the CDC can enhance clinical specificity. However, the suboptimal rates of test positivity found at time of hospitalization in this cohort underline the importance of molecular diagnostics to rule out/confirm active infection with SARS-CoV-2.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • BACKGROUND: The global market for SARS-CoV-2-immunoassays is becoming ever more crowded with antibody-tests of various formats, targets and technologies, careful evaluation is crucial for understanding the implications of individual test results. Here, we evaluate the clinical performance of five automated immunoassays on a set of clinical samples. METHODS: Serum/plasma samples of 75 confirmed COVID-19 patients and 320 pre-pandemic serum samples of healthy blood donors were subjected to two IgG and three total antibody SARS-CoV-2-immunoassays. All test setups were automated workflows. RESULTS: Positivity of assays (onset of symptoms > 10 days) ranged between 68.4% and 81.6% (Diasorin 68.4%, Euroimmun 70.3%, Siemens 73.7%, Roche 79.0% and Wantai 81.6%). All examined assays demonstrated high specificity of >99% (Euroimmun, Diasorin: 99.1%, Wantai: 99.4%) but only two reached levels above 99.5% (Roche: 99.7%, Siemens 100%). Interestingly, there was no overlap in false positive results between the assays. The strongest correlation of quantitative results was observed between the Diasorin and Euroimmun IgG tests (r(2) = 0.76). Overall, we observed no difference in the distribution of test results between female and male patients (p-values: 0.18-0.87). A significant difference between severely versus critically ill patients was demonstrated for the Euroimmun, Diasorin, Wantai and Siemens assays (p-values < 0.041). CONCLUSION: All assays showed good clinical performance. Our data confirm that orthogonal test strategies as recommended by the CDC can enhance clinical specificity. However, the suboptimal rates of test positivity found at time of hospitalization in this cohort underline the importance of molecular diagnostics to rule out/confirm active infection with SARS-CoV-2.
subject
  • Centers for Disease Control and Prevention
  • Musical groups from Mexico City
  • Organizations established in 1988
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software