About: To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In order to compare NIPE and CBS values during the whole T1 to T3 period, the variable Dif-CBS was defined as the difference between maximal and minimal CBS scores, and Dif-NIPE as the difference between 75th and 25th percentile NIPE values. Analyses were carried out, firstly for the total of nebulizations and secondly comparing two different nebulization systems: a jet nebulizer (JN) and a nebulizer integrated in high flow nasal cannulas (NHF). 84 nebulizations were recorded on 14 patients with a median [25th–75th percentile] age of 6 months (3.1–9.5). A Dif-CBS of 4 points (2–7), as well as changes in CBS scores between T1 and T2, defined the nebulization as a discomfort stimulus. The NIPE system, represented as the Dif-NIPE, showed a median variation of 9 points (7–10), and was poorly correlated to Dif-CBS [r(s) 0.162 (P = 0.142)]. Discomfort during nebulization, assessed by CBS was greater with the JN system compared to NHF: 17 (13–22) vs 13 (9–15) (P = 0.001). NIPE monitoring detected no significant differences between both nebulization systems (P = 0.706). NIPE monitoring showed a variation in comfort during nebulization in the patient with bronchiolitis, though correlation with CBS was poor. Further research is required before NIPE can be suggested as a comfort monitoring system for the awake infant.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • To compare the newborn infant parasympathetic evaluation system (NIPE) scores with a validated clinical scale using two different nebulizers in children with bronchiolitis admitted to a PICU. Comfort was evaluated using the COMFORT-behavior scale (CBS) before (T1), during (T2) and after (T3) each nebulization. In order to compare NIPE and CBS values during the whole T1 to T3 period, the variable Dif-CBS was defined as the difference between maximal and minimal CBS scores, and Dif-NIPE as the difference between 75th and 25th percentile NIPE values. Analyses were carried out, firstly for the total of nebulizations and secondly comparing two different nebulization systems: a jet nebulizer (JN) and a nebulizer integrated in high flow nasal cannulas (NHF). 84 nebulizations were recorded on 14 patients with a median [25th–75th percentile] age of 6 months (3.1–9.5). A Dif-CBS of 4 points (2–7), as well as changes in CBS scores between T1 and T2, defined the nebulization as a discomfort stimulus. The NIPE system, represented as the Dif-NIPE, showed a median variation of 9 points (7–10), and was poorly correlated to Dif-CBS [r(s) 0.162 (P = 0.142)]. Discomfort during nebulization, assessed by CBS was greater with the JN system compared to NHF: 17 (13–22) vs 13 (9–15) (P = 0.001). NIPE monitoring detected no significant differences between both nebulization systems (P = 0.706). NIPE monitoring showed a variation in comfort during nebulization in the patient with bronchiolitis, though correlation with CBS was poor. Further research is required before NIPE can be suggested as a comfort monitoring system for the awake infant.
Subject
  • Pediatrics
  • Aerosols
  • Medical equipment
  • Respiratory therapy
  • American television networks
  • Peabody Award winners
  • Drug delivery devices
  • Dosage forms
  • 1927 establishments in New York (state)
  • CBS Television Network
  • Fuji News Network
  • New York Yankees owners
  • American companies established in 1927
  • ViacomCBS subsidiaries
  • Television channels and stations established in 1927
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software