About: There is an urgent need for reliable high-throughput serological assays for the management of the ongoing COVID-19 pandemic. Preferably, the performance of serological tests for a novel virus should be determined with clinical specimens against a gold standard, i.e. virus neutralisation. We evaluated specificity and sensitivity of six commercial immunoassays for the detection of SARS-CoV-2 IgG, IgA and IgM antibodies, including four automated assays [Abbott SARS-COV-2 IgG (CE marked), Diasorin Liaison SARS-CoV-2 S1/S2 IgG (research use only), and Euroimmun SARS-CoV-2 IgG and IgA (CE marked)], and two rapid lateral flow (immunocromatographic) tests [Acro Biotech 2019-nCoV IgG/IgM (CE marked) and Xiamen Biotime Biotechnology SARS-CoV-2 IgG/IgM (CE marked)] in comparison with a microneutralisation test (MNT). Two specimen panels from serum samples sent to Helsinki University Hospital Laboratory (HUSLAB) were compiled: the patient panel included sera from PCR confirmed COVID-19 patients, and the negative panel included sera sent for screening of autoimmune diseases and respiratory virus antibodies in 2018 and 2019. The MNT was carried out for all COVID-19 samples (70 serum samples, 62 individuals) and for 53 samples from the negative panel. Forty-one out of 62 COVID-19 patients showed neutralising antibodies with median of 11 days (range 3-51) after onset of symptoms. The specificity and sensitivity values of the commercial tests against MNT, respectively, were as follows: 95.1%/80.5% (Abbott Architect SARS-CoV-2 IgG), 94.9%/43.8% (Diasorin Liaison SARS-CoV-2 IgG), 68.3%/87.8% (Euroimmun SARS-CoV-2 IgA), 86.6%/70.7% (Euroimmun SARS-CoV-2 IgG), 74.4%/56.1% (Acro 2019-nCoV IgG), 69.5%/46.3% (Acro 2019-nCoV IgM), 97.5%/71.9% (Xiamen Biotime SARS-CoV-2 IgG), and 88.8%/81.3% (Xiamen Biotime SARS-CoV-2 IgM). This study shows variable performance values. Laboratories should carefully consider their testing process, such as a two-tier approach, in order to optimize the overall performance of SARS-CoV-2 serodiagnostics.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • There is an urgent need for reliable high-throughput serological assays for the management of the ongoing COVID-19 pandemic. Preferably, the performance of serological tests for a novel virus should be determined with clinical specimens against a gold standard, i.e. virus neutralisation. We evaluated specificity and sensitivity of six commercial immunoassays for the detection of SARS-CoV-2 IgG, IgA and IgM antibodies, including four automated assays [Abbott SARS-COV-2 IgG (CE marked), Diasorin Liaison SARS-CoV-2 S1/S2 IgG (research use only), and Euroimmun SARS-CoV-2 IgG and IgA (CE marked)], and two rapid lateral flow (immunocromatographic) tests [Acro Biotech 2019-nCoV IgG/IgM (CE marked) and Xiamen Biotime Biotechnology SARS-CoV-2 IgG/IgM (CE marked)] in comparison with a microneutralisation test (MNT). Two specimen panels from serum samples sent to Helsinki University Hospital Laboratory (HUSLAB) were compiled: the patient panel included sera from PCR confirmed COVID-19 patients, and the negative panel included sera sent for screening of autoimmune diseases and respiratory virus antibodies in 2018 and 2019. The MNT was carried out for all COVID-19 samples (70 serum samples, 62 individuals) and for 53 samples from the negative panel. Forty-one out of 62 COVID-19 patients showed neutralising antibodies with median of 11 days (range 3-51) after onset of symptoms. The specificity and sensitivity values of the commercial tests against MNT, respectively, were as follows: 95.1%/80.5% (Abbott Architect SARS-CoV-2 IgG), 94.9%/43.8% (Diasorin Liaison SARS-CoV-2 IgG), 68.3%/87.8% (Euroimmun SARS-CoV-2 IgA), 86.6%/70.7% (Euroimmun SARS-CoV-2 IgG), 74.4%/56.1% (Acro 2019-nCoV IgG), 69.5%/46.3% (Acro 2019-nCoV IgM), 97.5%/71.9% (Xiamen Biotime SARS-CoV-2 IgG), and 88.8%/81.3% (Xiamen Biotime SARS-CoV-2 IgM). This study shows variable performance values. Laboratories should carefully consider their testing process, such as a two-tier approach, in order to optimize the overall performance of SARS-CoV-2 serodiagnostics.
Subject
  • Virology
  • Serology
  • Viruses
  • Epidemiology
  • Clinical pathology
  • Blood tests
  • Immunologic tests
  • Medical tests
  • 1898 in biology
  • COVID-19 pandemic in Asia
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software