About: BACKGROUND: Surgical N95 filtering facepiece respirators (FFRs), certified by the National Institute for Occupational Safety and Health (NIOSH) as a respirator and cleared by the Food and Drug Administration (FDA) as a surgical mask, are often used to protect from the inhalation of infectious aerosols and from splashes/sprays of body fluids in health care facilities. A shortage of respirators can be expected during a pandemic. The availability of surgical N95 FFRs can potentially be increased by incorporating FDA clearance requirements in the NIOSH respirator approval process. METHODS: Fluid resistance of NIOSH-approved N95 FFRs, and FDA-cleared surgical N95 FFRs and surgical masks was tested using the ASTM F1862 method at 450 and 635 cm/sec velocities and compared with the results from a third-party independent laboratory. Blood penetration through different layers of filter media of masks were also analyzed visually. RESULTS: Four N95 FFR models showed no test failures at both velocities. The penetration results obtained in the NIOSH laboratory were comparable to those from the third-party independent laboratory. The number of respirator samples failing the test increased with increasing test velocity. CONCLUSIONS: The results indicate that several NIOSH-approved N95 FFR models would likely pass FD clearance requirements for resistance to synthetic blood penetration.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • BACKGROUND: Surgical N95 filtering facepiece respirators (FFRs), certified by the National Institute for Occupational Safety and Health (NIOSH) as a respirator and cleared by the Food and Drug Administration (FDA) as a surgical mask, are often used to protect from the inhalation of infectious aerosols and from splashes/sprays of body fluids in health care facilities. A shortage of respirators can be expected during a pandemic. The availability of surgical N95 FFRs can potentially be increased by incorporating FDA clearance requirements in the NIOSH respirator approval process. METHODS: Fluid resistance of NIOSH-approved N95 FFRs, and FDA-cleared surgical N95 FFRs and surgical masks was tested using the ASTM F1862 method at 450 and 635 cm/sec velocities and compared with the results from a third-party independent laboratory. Blood penetration through different layers of filter media of masks were also analyzed visually. RESULTS: Four N95 FFR models showed no test failures at both velocities. The penetration results obtained in the NIOSH laboratory were comparable to those from the third-party independent laboratory. The number of respirator samples failing the test increased with increasing test velocity. CONCLUSIONS: The results indicate that several NIOSH-approved N95 FFR models would likely pass FD clearance requirements for resistance to synthetic blood penetration.
subject
  • Primary care
  • Physical chemistry
  • Medical masks
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software