About: OBJECTIVE: To compare the effect of self-inflating bag (SIB) vs. T-piece resuscitator (TPR) on PaCO(2) levels, when used for brief manual ventilation during administration of first dose of surfactant. METHODS: Preterm neonates were randomized to receive positive pressure ventilation with either self-inflating bag or T-piece resuscitator during administration of first dose of surfactant. Arterial blood gases were obtained at baseline and 1 h after the intervention. Primary outcome was the mean change in PaCO(2) levels 1 h after the intervention. RESULTS: Eighty neonates were enrolled (40 in each group). The drop in PaCO(2) at 1 h was significantly greater in the self inflating bag group as compared to the T-piece resuscitator group [8.96 ± 9.06 mmHg vs. 1.37 ± 9.06 mmHg, Mean difference = 7.58 mmHg, (95% CI: 3.78 to 11.4); P < 0.01]. The PaCO(2) change was also statistically significant in the subgroup of infants that required only non-invasive ventilation. The need for second dose of surfactant was higher in the self-inflating bag group [77% vs. 55%, RR - 1.41 (95% CI: 1.02 to 1.94); P = 0.03]. CONCLUSIONS: T-piece resuscitator results in smaller reduction in PaCO(2) levels compared to the self inflating bag, when used for brief manual ventilation during surfactant administration.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • OBJECTIVE: To compare the effect of self-inflating bag (SIB) vs. T-piece resuscitator (TPR) on PaCO(2) levels, when used for brief manual ventilation during administration of first dose of surfactant. METHODS: Preterm neonates were randomized to receive positive pressure ventilation with either self-inflating bag or T-piece resuscitator during administration of first dose of surfactant. Arterial blood gases were obtained at baseline and 1 h after the intervention. Primary outcome was the mean change in PaCO(2) levels 1 h after the intervention. RESULTS: Eighty neonates were enrolled (40 in each group). The drop in PaCO(2) at 1 h was significantly greater in the self inflating bag group as compared to the T-piece resuscitator group [8.96 ± 9.06 mmHg vs. 1.37 ± 9.06 mmHg, Mean difference = 7.58 mmHg, (95% CI: 3.78 to 11.4); P < 0.01]. The PaCO(2) change was also statistically significant in the subgroup of infants that required only non-invasive ventilation. The need for second dose of surfactant was higher in the self-inflating bag group [77% vs. 55%, RR - 1.41 (95% CI: 1.02 to 1.94); P = 0.03]. CONCLUSIONS: T-piece resuscitator results in smaller reduction in PaCO(2) levels compared to the self inflating bag, when used for brief manual ventilation during surfactant administration.
Subject
  • Biotechnology
  • Surfactants
  • Colloidal chemistry
  • Cleaning product components
  • Environmental terminology
  • Underwater diving physics
  • Bioremediation
  • Diagnostic intensive care medicine
  • Fifth Colvmn Records albums
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software