About: Coronavirus disease 2019 (COVID-19) has created an unprecedented need for breathing assistance devices. Since the demand for commercial, full-featured ventilators is far higher than the supply capacity, many rapid-response ventilators are being developed for invasive mechanical ventilation of patients. Most of these emergency ventilators utilize mechanical squeezing of bag-valve-masks or Ambu-bags. These%22bag squeezer%22designs are bulky and heavy, depends on many moving parts, and difficulty to assemble and use. Also, invasive ventilation requires intensive care unit support, which may be unavailable to a vast majority of patients, especially in developing countries. In this work, we present a low-cost ($<$/$200), portable (fits in an 8%22x8%22x4%22box), non-invasive ventilator (NIV), designed to provide relief to early-stage COVID-19 patients in low-resource settings. We used a high-pressure blower fan for providing noninvasive positive-pressure ventilation. Our design supports continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP) modes. A common concern of using CPAP or BiPAP for treating COVID-19 patients is the aerosolization of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We used a helmet-based solution that contains the spread of the virus. Our end-to-end solution is compact, low-cost ($<$/$400 including the helmet, viral filters, and a valve), and easy-to-use. Our NIV provides 0-20 cmH$_{2}$O pressure with flow rates of 60-180 Lmin$^{-1}$. We hope that our report will encourage implementations and further studies on helmet-based NIV for treating COVID-19 patients in low-resource settings.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • Coronavirus disease 2019 (COVID-19) has created an unprecedented need for breathing assistance devices. Since the demand for commercial, full-featured ventilators is far higher than the supply capacity, many rapid-response ventilators are being developed for invasive mechanical ventilation of patients. Most of these emergency ventilators utilize mechanical squeezing of bag-valve-masks or Ambu-bags. These%22bag squeezer%22designs are bulky and heavy, depends on many moving parts, and difficulty to assemble and use. Also, invasive ventilation requires intensive care unit support, which may be unavailable to a vast majority of patients, especially in developing countries. In this work, we present a low-cost ($<$/$200), portable (fits in an 8%22x8%22x4%22box), non-invasive ventilator (NIV), designed to provide relief to early-stage COVID-19 patients in low-resource settings. We used a high-pressure blower fan for providing noninvasive positive-pressure ventilation. Our design supports continuous positive airway pressure (CPAP) and bilevel positive airway pressure (BiPAP) modes. A common concern of using CPAP or BiPAP for treating COVID-19 patients is the aerosolization of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We used a helmet-based solution that contains the spread of the virus. Our end-to-end solution is compact, low-cost ($<$/$400 including the helmet, viral filters, and a valve), and easy-to-use. Our NIV provides 0-20 cmH$_{2}$O pressure with flow rates of 60-180 Lmin$^{-1}$. We hope that our report will encourage implementations and further studies on helmet-based NIV for treating COVID-19 patients in low-resource settings.
Subject
  • Virology
  • Zoonoses
  • Mechanical ventilation
  • Intensive care medicine
  • Economic geography
  • COVID-19
  • Emergency medicine
  • Medical equipment
  • Respiratory system procedures
  • Medical pumps
  • Treatment of sleep disorders
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software