About: Abstract Several commercial assays are now available to detect the nucleic acid of multiple respiratory pathogens from a single specimen. Head-to-head comparisons of such assays using a single set of standard specimens provide additional information about key assay parameters such as sensitivity, specificity and lower limits of detection, and help to inform the decision regarding which method to use. We evaluated two real-time PCR platforms: the Fast-track Diagnostics® (FTD) multiplex respiratory panel and a TaqMan array card (TAC) for simultaneous uniplex detection of multiple respiratory pathogens. Two sets of samples were used to evaluate the assays. One set was created by spiking pooled nasal wash or phosphate buffered saline with specified volumes of known concentrations of virus and/or bacteria. Clinical nasal wash specimens from children with lower respiratory tract illness comprised the other set. Thirteen pathogen targets were compared between the two platforms. Testing with a validation panel of spiked samples revealed a sensitivity of 96.1% and 92.9% for the FTD and TAC assays, respectively. Specificity could not be reliably calculated due to a suspected contamination of the sample substrate. Inter-assay agreement was high (>95%) for most targets. Previously untested clinical specimens tested by both assays revealed a high percent agreement (>95%) for all except rhinovirus, enterovirus and Streptococcus pneumoniae. Limitations of this evaluation included extraction of the validation samples by two different methods and the evaluation of the assays in different laboratories. However, neither of these factors significantly impacted inter-assay agreement for these sets of samples, and it was demonstrated that both assays could reliably detect clinically relevant concentrations of bacterial and viral pathogens.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • Abstract Several commercial assays are now available to detect the nucleic acid of multiple respiratory pathogens from a single specimen. Head-to-head comparisons of such assays using a single set of standard specimens provide additional information about key assay parameters such as sensitivity, specificity and lower limits of detection, and help to inform the decision regarding which method to use. We evaluated two real-time PCR platforms: the Fast-track Diagnostics® (FTD) multiplex respiratory panel and a TaqMan array card (TAC) for simultaneous uniplex detection of multiple respiratory pathogens. Two sets of samples were used to evaluate the assays. One set was created by spiking pooled nasal wash or phosphate buffered saline with specified volumes of known concentrations of virus and/or bacteria. Clinical nasal wash specimens from children with lower respiratory tract illness comprised the other set. Thirteen pathogen targets were compared between the two platforms. Testing with a validation panel of spiked samples revealed a sensitivity of 96.1% and 92.9% for the FTD and TAC assays, respectively. Specificity could not be reliably calculated due to a suspected contamination of the sample substrate. Inter-assay agreement was high (>95%) for most targets. Previously untested clinical specimens tested by both assays revealed a high percent agreement (>95%) for all except rhinovirus, enterovirus and Streptococcus pneumoniae. Limitations of this evaluation included extraction of the validation samples by two different methods and the evaluation of the assays in different laboratories. However, neither of these factors significantly impacted inter-assay agreement for these sets of samples, and it was demonstrated that both assays could reliably detect clinically relevant concentrations of bacterial and viral pathogens.
subject
  • Virology
  • Bacteria
  • Infectious diseases
  • Virus genera
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software