About: Artifact Detection (AD) techniques minimize the impact of artifacts on physiologic data acquired in Critical Care Units (CCU) by assessing quality of data prior to Clinical Event Detection (CED) and Parameter Derivation (PD). This methodological review introduces unique taxonomies to synthesize over 80 AD algorithms based on these six themes: (1) CCU; (2) Physiologic Data Source; (3) Harvested data; (4) Data Analysis; (5) Clinical Evaluation; and (6) Clinical Implementation. Review results show that most published algorithms: (a) are designed for one specific type of CCU; (b) are validated on data harvested only from one Original Equipment Manufacturer (OEM) monitor; (c) generate Signal Quality Indicators (SQI) that are not yet formalised for useful integration in clinical workflows; (d) operate either in standalone mode or coupled with CED or PD applications; (e) are rarely evaluated in real-time; and (f) are not implemented in clinical practice. In conclusion, it is recommended that AD algorithms conform to generic input and output interfaces with commonly defined data: (1) type; (2) frequency; (3) length; and (4) SQIs. This shall promote (a) reusability of algorithms across different CCU domains; (b) evaluation on different OEM monitor data; (c) fair comparison through formalised SQIs; (d) meaningful integration with other AD, CED and PD algorithms; and (e) real-time implementation in clinical workflows.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • Artifact Detection (AD) techniques minimize the impact of artifacts on physiologic data acquired in Critical Care Units (CCU) by assessing quality of data prior to Clinical Event Detection (CED) and Parameter Derivation (PD). This methodological review introduces unique taxonomies to synthesize over 80 AD algorithms based on these six themes: (1) CCU; (2) Physiologic Data Source; (3) Harvested data; (4) Data Analysis; (5) Clinical Evaluation; and (6) Clinical Implementation. Review results show that most published algorithms: (a) are designed for one specific type of CCU; (b) are validated on data harvested only from one Original Equipment Manufacturer (OEM) monitor; (c) generate Signal Quality Indicators (SQI) that are not yet formalised for useful integration in clinical workflows; (d) operate either in standalone mode or coupled with CED or PD applications; (e) are rarely evaluated in real-time; and (f) are not implemented in clinical practice. In conclusion, it is recommended that AD algorithms conform to generic input and output interfaces with commonly defined data: (1) type; (2) frequency; (3) length; and (4) SQIs. This shall promote (a) reusability of algorithms across different CCU domains; (b) evaluation on different OEM monitor data; (c) fair comparison through formalised SQIs; (d) meaningful integration with other AD, CED and PD algorithms; and (e) real-time implementation in clinical workflows.
Subject
  • Digital electronics
  • Telecommunication theory
  • Psychophysics
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software