About: BACKGROUND: Over the past years, several emergency medical service providers have introduced mechanical chest compression devices (MCDs) in their protocols for cardiopulmonary resuscitation (CPR). Especially in helicopter emergency medical systems (HEMS), which have limitations regarding loading weight and space and typically operate in rural and remote areas, whether MCDs have benefits for patients is still unknown. The aim of this study was to evaluate the use of MCDs in a large Swiss HEMS system. MATERIALS AND METHODS: We conducted a retrospective observational study of all HEMS missions of Swiss Air rescue Rega between January 2014 and June 2016 with the use of an MCD (Autopulse®). Details of MCD use and patient outcome are reported from the medical operation journals and the hospitals’ discharge letters. RESULTS: MCDs were used in 626 HEMS missions, and 590 patients (94%) could be included. 478 (81%) were primary missions and 112 (19%) were interhospital transfers. Forty-nine of the patients in primary missions were loaded under ongoing CPR with MCDs. Of the patients loaded after return of spontaneous circulation (ROSC), 20 (7%) experienced a second CA during the flight. In interhospital transfers, 102 (91%) only needed standby use of the MCD. Five (5%) patients were loaded into the helicopter with ongoing CPR. Five (5%) patients went into CA during flight and the MCD had to be activated. A shockable cardiac arrhythmia was the only factor significantly associated with better survival in resuscitation missions using MCD (OR 0.176, 95% confidence interval 0.084 to 0.372, p < 0.001). CONCLUSION: We conclude that equipping HEMS with MCDs may be beneficial, with non-trauma patients potentially benefitting more than trauma patients.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • BACKGROUND: Over the past years, several emergency medical service providers have introduced mechanical chest compression devices (MCDs) in their protocols for cardiopulmonary resuscitation (CPR). Especially in helicopter emergency medical systems (HEMS), which have limitations regarding loading weight and space and typically operate in rural and remote areas, whether MCDs have benefits for patients is still unknown. The aim of this study was to evaluate the use of MCDs in a large Swiss HEMS system. MATERIALS AND METHODS: We conducted a retrospective observational study of all HEMS missions of Swiss Air rescue Rega between January 2014 and June 2016 with the use of an MCD (Autopulse®). Details of MCD use and patient outcome are reported from the medical operation journals and the hospitals’ discharge letters. RESULTS: MCDs were used in 626 HEMS missions, and 590 patients (94%) could be included. 478 (81%) were primary missions and 112 (19%) were interhospital transfers. Forty-nine of the patients in primary missions were loaded under ongoing CPR with MCDs. Of the patients loaded after return of spontaneous circulation (ROSC), 20 (7%) experienced a second CA during the flight. In interhospital transfers, 102 (91%) only needed standby use of the MCD. Five (5%) patients were loaded into the helicopter with ongoing CPR. Five (5%) patients went into CA during flight and the MCD had to be activated. A shockable cardiac arrhythmia was the only factor significantly associated with better survival in resuscitation missions using MCD (OR 0.176, 95% confidence interval 0.084 to 0.372, p < 0.001). CONCLUSION: We conclude that equipping HEMS with MCDs may be beneficial, with non-trauma patients potentially benefitting more than trauma patients.
subject
  • Cardiopulmonary resuscitation
  • Causes of death
  • Emergency medical services
  • Emergency medicine
  • Air ambulance services
  • Rescue aviation
  • Chamber of Deputies (Romania)
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software