About: The SARS-CoV-2 pandemic has challenged molecular microbiology laboratories to quickly implement and validate diagnostic assays and to expand testing capacity in a short timeframe. Multiple molecular diagnostic methods received FDA emergency use authorization (EUA) and were promptly validated for use nationwide. Several studies reported the analytical and/ or clinical evaluation of these molecular assays, however differences in the viral materials used for these evaluations complicated direct comparison of their analytical performance. In this study, we compared the analytical sensitivity (lower limit of detection, LOD) of seven commonly used qualitative SARS-CoV-2 molecular assays: the Abbott Molecular RealTime SARS-CoV-2 assay, the NeuMoDx™ SARS-CoV-2 assay, the Roche Cobas®SARS-CoV-2 assay, the BD SARS-CoV-2 reagents for BD MAX™ system, the Hologic Aptima® SARS-CoV-2 assay, the Xpert Xpress SARS-CoV-2 test, and the GenMark ePlex SARS-CoV-2 test. The comparison was performed utilizing a single positive clinical specimen that was serially diluted in viral transport media and quantified by the EUA approved SARS-CoV-2 droplet digital PCR (ddPCR) assay. Replicate samples were prepared and evaluated for reproducibility across different molecular assays with multiple replicates per assay. Our data demonstrated that the seven assays could detect 100% of replicates at a nucleocapsid gene concentration of (N1 = 1,267 and N2 = 1,392) copies/mL. At a one log less concentration, the Abbott, the Roche, and the Xpert Xpress assays detected 100% of the tested replicates.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • The SARS-CoV-2 pandemic has challenged molecular microbiology laboratories to quickly implement and validate diagnostic assays and to expand testing capacity in a short timeframe. Multiple molecular diagnostic methods received FDA emergency use authorization (EUA) and were promptly validated for use nationwide. Several studies reported the analytical and/ or clinical evaluation of these molecular assays, however differences in the viral materials used for these evaluations complicated direct comparison of their analytical performance. In this study, we compared the analytical sensitivity (lower limit of detection, LOD) of seven commonly used qualitative SARS-CoV-2 molecular assays: the Abbott Molecular RealTime SARS-CoV-2 assay, the NeuMoDx™ SARS-CoV-2 assay, the Roche Cobas®SARS-CoV-2 assay, the BD SARS-CoV-2 reagents for BD MAX™ system, the Hologic Aptima® SARS-CoV-2 assay, the Xpert Xpress SARS-CoV-2 test, and the GenMark ePlex SARS-CoV-2 test. The comparison was performed utilizing a single positive clinical specimen that was serially diluted in viral transport media and quantified by the EUA approved SARS-CoV-2 droplet digital PCR (ddPCR) assay. Replicate samples were prepared and evaluated for reproducibility across different molecular assays with multiple replicates per assay. Our data demonstrated that the seven assays could detect 100% of replicates at a nucleocapsid gene concentration of (N1 = 1,267 and N2 = 1,392) copies/mL. At a one log less concentration, the Abbott, the Roche, and the Xpert Xpress assays detected 100% of the tested replicates.
Subject
  • Zoonoses
  • COVID-19
  • Price fixing convictions
  • Sarbecovirus
  • Chiroptera-borne diseases
  • Infraspecific virus taxa
  • Companies established in 1996
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.