Facets (new session)
Description
Metadata
Settings
owl:sameAs
Inference Rule:
b3s
b3sifp
dbprdf-label
facets
http://dbpedia.org/resource/inference/rules/dbpedia#
http://dbpedia.org/resource/inference/rules/opencyc#
http://dbpedia.org/resource/inference/rules/umbel#
http://dbpedia.org/resource/inference/rules/yago#
http://dbpedia.org/schema/property_rules#
http://www.ontologyportal.org/inference/rules/SUMO#
http://www.ontologyportal.org/inference/rules/WordNet#
http://www.w3.org/2002/07/owl#
ldp
oplweb
skos-trans
virtrdf-label
None
About:
Acute Shortage Ventilator
Goto
Sponge
NotDistinct
Permalink
An Entity of Type :
schema:ScholarlyArticle
, within Data Space :
wasabi.inria.fr
associated with source
document(s)
Type:
Academic Article
research paper
schema:ScholarlyArticle
New Facet based on Instances of this Class
Attributes
Values
type
Academic Article
research paper
schema:ScholarlyArticle
isDefinedBy
Covid-on-the-Web dataset
has title
Acute Shortage Ventilator
Creator
Miller, E
Charles, E
Akerib, D
Ames, A
Breidenbach, M
Bressack, M
Breur, P
Gaba, D
Herbst, R
Ignarra, C
Luitz, S
Mong, B
Shutt, T
Wittgen, M
Source
MedRxiv
abstract
We have implemented an ''Acute Shortage Ventilator'' (ASV) motivated by the COVID-19 pandemic and the possibility of severe ventilator shortages in the near future. The unit cost per ventilator is less than $400 US excluding the patient circuit parts. The ASV mechanically compresses a self-inflating bag resuscitator, uses a modified patient circuit, and is commanded by a microcontroller and an optional laptop. It operates in both Volume-Controlled Assist-Control mode and a Pressure-Controlled Assist-Control mode. It has been tested using an artificial lung against the EURS guidelines. The key design goals were to develop a simple device with high performance for short-term use, made primarily from common hospital parts and generally-available non-medical components, and at low cost and ease in manufacturing.
has issue date
2020-07-25
(
xsd:dateTime
)
bibo:doi
10.1101/2020.07.20.20158147
has license
medrxiv
sha1sum (hex)
ea36a8d6526183c162f5af15f7be5d2e2a5941b4
schema:url
https://doi.org/10.1101/2020.07.20.20158147
resource representing a document's title
Acute Shortage Ventilator
resource representing a document's body
covid:ea36a8d6526183c162f5af15f7be5d2e2a5941b4#body_text
is
schema:about
of
named entity 'MEDICAL'
named entity 'SIMPLE'
named entity 'ASSIST'
named entity 'IMPLEMENTED'
named entity 'DESIGN'
named entity 'unit cost'
named entity 'microcontroller'
named entity 'LCD display'
named entity 'medRxiv'
named entity 'ICU'
named entity 'differential pressure'
named entity 'lung compliance'
named entity 'pneumatic'
named entity 'scfm'
named entity 'compressed air'
named entity 'ventilator'
named entity 'mechanical systems'
named entity 'sensor'
named entity 'endotracheal tube'
named entity 'ARDS'
named entity 'oxygen consumption'
named entity 'laptop'
named entity 'Graphical User Interface'
named entity 'data analysis'
named entity 'ventilator'
named entity 'medRxiv'
named entity 'flow measurement'
named entity 'serial cable'
named entity 'PEEP'
named entity 'peer review'
named entity 'DOE'
named entity 'HEPA'
named entity 'pressure-volume curves'
named entity 'endotracheal tube'
named entity 'CC-BY-NC 4.0'
named entity 'GUI'
named entity 'respiratory rates'
named entity 'SLAC National Accelerator Laboratory'
named entity 'pneumatic'
named entity 'MCUs'
named entity 'simulated patient'
named entity 'pneumatic cylinder'
named entity 'SLAC National Accelerator Laboratory'
named entity 'CC-BY-NC 4.0'
named entity 'pressure-volume curves'
named entity 'PMax'
named entity 'PIP'
named entity 'flowmeter'
named entity 'plywood'
named entity 'Santa Clara Valley Medical Center'
named entity 'data output'
named entity 'ARDS'
named entity 'ICU'
named entity 'tidal volume'
named entity 'rubber'
named entity 'respiratory rate'
named entity 'needle valve'
named entity 'pneumatic cylinder'
named entity 'spirometer'
named entity 'ARDS'
named entity 'CC-BY-NC 4.0'
named entity 'Respiration Rate'
named entity 'ISO'
named entity 'ventilator'
named entity 'spirometer'
named entity 'spirometer'
named entity 'ventilator'
named entity 'tidal volume'
named entity 'COVID-19'
named entity 'COVID-19'
named entity 'blue line'
named entity 'pressure gauge'
◂◂ First
◂ Prev
Next ▸
Last ▸▸
Page 1 of 5
Go
Faceted Search & Find service v1.13.91 as of Mar 24 2020
Alternative Linked Data Documents:
Sponger
|
ODE
Content Formats:
RDF
ODATA
Microdata
About
OpenLink Virtuoso
version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software