About: A real-time reverse transcription loop-mediated isothermal amplification (real-time RT-LAMP) method was applied for detecting the replicase polyprotein-encoding gene of yellow head virus (YHV) in shrimp, Penaeus monodon. It is a novel, gene-specific assay that amplifies nucleic acid with high specificity, sensitivity and rapidity under isothermal conditions using a set of six specially designed primers that recognize eight distinct sequences of the target gene. This method works with even low copies of DNA and is based on magnesium pyrophosphate turbidity detection by an inexpensive photometer for quantitative analysis. A user-friendly protocol was developed with optimal conditions standardized at 63 °C for 60 min. With this protocol, the assay sensitivity was 10 times higher than the widely used YHV nested RT-PCR system. Cross-reactivity analysis using other shrimp virus DNA/cDNA and YHV-negative shrimp demonstrated high specificity of the assay. The real-time RT-LAMP method was performed also for an internal control gene, EF-1α, to compare with the expressions of the YHV gene in different organs of infected shrimp, and the resulting standard curves showed high correlation coefficient values. These results suggest that this assay is applicable widely as a new quantitative detection method in the pursuit of YHV-free shrimp culture.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • A real-time reverse transcription loop-mediated isothermal amplification (real-time RT-LAMP) method was applied for detecting the replicase polyprotein-encoding gene of yellow head virus (YHV) in shrimp, Penaeus monodon. It is a novel, gene-specific assay that amplifies nucleic acid with high specificity, sensitivity and rapidity under isothermal conditions using a set of six specially designed primers that recognize eight distinct sequences of the target gene. This method works with even low copies of DNA and is based on magnesium pyrophosphate turbidity detection by an inexpensive photometer for quantitative analysis. A user-friendly protocol was developed with optimal conditions standardized at 63 °C for 60 min. With this protocol, the assay sensitivity was 10 times higher than the widely used YHV nested RT-PCR system. Cross-reactivity analysis using other shrimp virus DNA/cDNA and YHV-negative shrimp demonstrated high specificity of the assay. The real-time RT-LAMP method was performed also for an internal control gene, EF-1α, to compare with the expressions of the YHV gene in different organs of infected shrimp, and the resulting standard curves showed high correlation coefficient values. These results suggest that this assay is applicable widely as a new quantitative detection method in the pursuit of YHV-free shrimp culture.
Subject
  • Virology
  • Cloning
  • Genes
  • Water pollution
  • Dietary minerals
  • Laboratory techniques
  • Molecular biology
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software