About: In situ physico-chemical disinfection of high risk faecal waste is both effective and widely used as a sanitation management strategy for infection prevention and control. Systematic tests where the performance of alternative physico-chemical disinfection methods is systematically compared and optimized must be based on reliable protocols. These protocol are currently not adequately addressing the neutralization related issues: the neutralization of the tested disinfectant after specified conditions of concentration and contact time (CT) is necessary to prevent continued disinfection after the intended contact time; moreover such neutralization is often necessary in practice and on a large scale to prevent adverse health and ecological impacts from remaining disinfectant after the target CT is achieved. Few studies adequately assess the extent of neutralization of the chemical disinfectant and are intended to optimize on-site disinfection practices for waste matrices posing high microbial risks. Hence, there is a need for effective and reproducible neutralization protocols in chemical disinfection trials and practice. Furthermore, for most of chemical disinfectants used in healthcare settings there is no practical methodology to reliably and conveniently measure the residual disinfectant concentration after its neutralization and also determine the optimum concentration of the neutralizer. Because some neutralizing compounds can themselves be toxic to the test microorganisms, it is necessary to optimize neutralization procedures in disinfection experiments for the development of infection control practices using accepted positive control microbes. In the presented work, a stepwise bioassay-based protocol using representative faecal indicator microbes is described for optimizing chemical disinfection and subsequent disinfectant neutralization of any infectious faecal waste matrix. The example described is for the quaternary ammonium compound benzalkonium chloride and its recommended chemical neutralizer in a high strength human faecal waste matrix.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : wasabi.inria.fr associated with source document(s)

AttributesValues
type
value
  • In situ physico-chemical disinfection of high risk faecal waste is both effective and widely used as a sanitation management strategy for infection prevention and control. Systematic tests where the performance of alternative physico-chemical disinfection methods is systematically compared and optimized must be based on reliable protocols. These protocol are currently not adequately addressing the neutralization related issues: the neutralization of the tested disinfectant after specified conditions of concentration and contact time (CT) is necessary to prevent continued disinfection after the intended contact time; moreover such neutralization is often necessary in practice and on a large scale to prevent adverse health and ecological impacts from remaining disinfectant after the target CT is achieved. Few studies adequately assess the extent of neutralization of the chemical disinfectant and are intended to optimize on-site disinfection practices for waste matrices posing high microbial risks. Hence, there is a need for effective and reproducible neutralization protocols in chemical disinfection trials and practice. Furthermore, for most of chemical disinfectants used in healthcare settings there is no practical methodology to reliably and conveniently measure the residual disinfectant concentration after its neutralization and also determine the optimum concentration of the neutralizer. Because some neutralizing compounds can themselves be toxic to the test microorganisms, it is necessary to optimize neutralization procedures in disinfection experiments for the development of infection control practices using accepted positive control microbes. In the presented work, a stepwise bioassay-based protocol using representative faecal indicator microbes is described for optimizing chemical disinfection and subsequent disinfectant neutralization of any infectious faecal waste matrix. The example described is for the quaternary ammonium compound benzalkonium chloride and its recommended chemical neutralizer in a high strength human faecal waste matrix.
Subject
  • Hygiene
  • Disinfectants
  • Bactericides
  • Sewerage
  • Water treatment
  • Hiking equipment
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software